<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-28 08-04-07
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 41 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 13 kHz 18570 0,0754
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,3 dBr -1,08 dBr 0,6 dBr 4,7
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 8:04, 28.12.2025
RT
"Analyzy a komentare - deni z domova i ze sveta "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 13 kHz MIN: 6 kHz % above 77 kHz: 0,0754 Acquired: 2025/12/28 8:04:04 Total samples: 18570 Equivalent time: 0:15:28 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 0,6 dBr MIN: -2,3 dBr AVE: -1,08 dBr % above 0,2 dBr: 4,7 Last value: -0,3 dBr (2025/12/28 8:04:03) 07:50 07:52 07:54 07:56 07:58 08:00 08:02 08:04 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality